
Nutanix NCSC-Level-1 Practice Verified Answers - Pass Your Exams For Sure! [2021]
Valid Way To Pass Nutanix SE Academy's NCSC-Level-1 Exam
NEW QUESTION 41
A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.
The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.
What is causing this issue?
- A. The host and CVM are incorrectly configured.
- B. The hosts have not been migrated to a vSphere Distributed Switch.
- C. The customer has LACP fallback enabled on switch ports.
- D. Under the vSwitch0 settings, the consultant did not select Route based on IP hash.
Answer: B
NEW QUESTION 42
A consultant is planning a new cluster installation and needs to locate the Shared IPMI port for each of the specific nodes that the customer has bought.
Which Support Portal location contains the document that would identify the port?
- A. Knowledge Base
- B. Solutions Documentation
- C. Hardware Replacement Documentation
- D. Software Documentation
Answer: C
NEW QUESTION 43
Where can a consultant find Nutanix Enablement Starter Packs (ESPs)?
- A. In the Services section of the Nutanix website.
- B. In the Support Portal
- C. In the Partner Portal
- D. In the Nutanix .NEXT Community Forum
Answer: C
NEW QUESTION 44
To prepare for a new Nutanix installation, a consultant downloads the Foundation VM, imports the VM to their Desktop Virtualization Solution, and powers on the VM. The IPv4 static address on the host workstation and the Foundation VM have been configured, but pings between them fail.
Which two troubleshooting steps should the consultant perform? (Choose two.)
- A. Verify the virtual NIC in the Foundation VM is bound to the correct physical Host adapter.
- B. Verify the virtual NIC in the Foundation VM is bound to the correct wireless network adapter.
- C. Confirm the IP addresses and subnet masks are correct.
- D. Remove and re-import the Foundation VM to ensure the virtual NIC is set to Host-Only.
Answer: A,C
NEW QUESTION 45
After uploading a hypervisor ISO during the Foundation process, a consultant sees a message that the MD5 sum for the hypervisor is not found in the Whitelist file.
Which step should the consultant take next to resolve this issue?
- A. Check the hypervisor version in the Nutanix Compatibility Matrix.
- B. Download the hypervisor ISO again from the vendor website.
- C. Restart the Foundation process and upload the hypervisor again.
- D. Download the latest hypervisor ISO whitelist file from Nutanix portal.
Answer: D
NEW QUESTION 46
A customer would like to re-image an existing cluster. The Foundation Applet and Foundation VM is unavailable to them.
How can the consultant access Foundation-as-a-Service (FaaS)?
- A. Through <CVM-IP> :9443
- B. Through <cluster-IP> :8000
- C. Through <cluster-IP> :9443
- D. Through <CVM-IP> :8000
Answer: D
NEW QUESTION 47
A customer buys ultimate licensing and wants to use the built-in Nutanix software encryption on their new AHV cluster. The customer needs to create three storage containers and asks the consultant to complete the process as fast as possible.
In which order should the cluster be deployed?
- A. Create Cluster -> Install License Key -> Create Storage Containers -> Encrypt Cluster
- B. Create Cluster -> Create Storage Containers -> Encrypt Cluster -> Install License Key
- C. Create Cluster -> Encrypt Cluster -> Install License Key -> Create Storage Containers
- D. Create Cluster -> Install License Key -> Encrypt Cluster -> Create Storage Containers
Answer: A
NEW QUESTION 48
After installation, network ports are properly configured with the default active-backup bonding.
One 10GbE port goes to switch 1. Another 10GbE port goes to switch 2. A consultant tests failover by manually pulling one of the cables and notices it is taking too much time to failover, which is causing excessive packet loss.
What should the consultant enable to resolve this issue?
- A. LACP on switch
- B. PAgP
- C. Jumbo frames
- D. Portfast
Answer: D
NEW QUESTION 49
A consultant is using the Foundation applet to create a cluster. During the process the consultant refreshes the progress bar web page and is concerned when nothing loads.
What should the consultant do to verify that Foundation has completed successfully?
- A. Return to the Foundation configuration page and start over.
- B. Restart the Foundation process.
- C. Connect to any CVM IP address from a web browser.
- D. Update Java on the Foundation VM.
Answer: C
NEW QUESTION 50
Which subnet is reserved for internal connectivity within a Nutanix Cluster?
- A. 192.168.5.0/26
- B. 192.168.254.0/24
- C. 192.168.5.0/24
- D. 192.168.5.0/23
Answer: C
NEW QUESTION 51
In a 20-node ESXi deployment, the customer needs additional resiliency to survive the loss of two nodes concurrently.
Which configuration should the consultant use to ensure that the appropriate resources are available?
- A. Storage reservation for 5%; HA admission control for 5%, cluster RF2
- B. Storage reservation for 10%; HA admission control for 10%, cluster RF2
- C. Storage reservation for 10%; HA admission control for 10%, cluster RF3
- D. Storage reservation for 5%; HA admission control for 5%, cluster RF3
Answer: C
NEW QUESTION 52
A consultant deploys a four-node VMware ESXi cluster and vCenter server. An HA/DRS cluster is configured for all four nodes. The customer deploys five new VMs on the cluster.
During the knowledge Transfer, a network cable on one node is removed to demonstrate HA and migration of the VMs to another host. In the HA/DRS cluster settings, the VM Restart Priority for all CVMs is set to Disabled. The customer observes warnings that the CVM on the ejected host is no longer powered on.
Which ESXi HA/DRS cluster setting is missing?
- A. Enable EVC for the cluster.
- B. Disable Automation Level on all CVMs.
- C. Disable VM Monitoring on all CVMs.
- D. Enable Host Monitoring.
Answer: B
NEW QUESTION 53
For a new AHV cluster installation, a customer has 20 NX-8155-G6 nodes with quad port SFP NICs.
The customer wants to meet the following guidelines:
* Take advantage of all available 10GbE links
* Achieve maximum throughput per VM
* Use of redundant ToR switches
* Fastest reconvergence during link failure
How should the load balancing be configured on the host?
- A. ovs-vsctl set port br0-up bond_mode=active-backup
ovs-vsctl set port br0-up other_config:bond-rebalance-interval=30000 - B. ovs-vsctl set port br0-up other_config:lacp-fallback-ab=true
ovs-vsctl set port br0-up lacp=active
ovs-vsctl set port br0-up bond_mode=balance-tcp - C. ovs-vsctl set port br0-up bond_mode=balance-slb
- D. ovs-vsctl set port br0-up bond_mode=balance-slb
ovs-vsctl set port br0-up other_config:bond-rebalance-interval=30000
ovs-vsctl set port br0 tag=10
Answer: D
NEW QUESTION 54
A consultant configures a Nutanix cluster and integrates the hosts into vCenter using VMware best practices. The customer has requested that the Nutanix cluster only have a single datastore.
Upon configuring the cluster per the customer requirements, vCenter displays an alert regarding the heartbeat datastore. The consultant adds the das.ignoreInsufficientHbDatastore value = true rule. The container can be seen from each host, but the alert remains active.
What should the consultant do to resolve this issue?
- A. Make sure the DRS setting is turned on.
- B. Turn off and then turn back on HA.
- C. Create a second container.
- D. Whitelist the vCenter IP address within Prism.
Answer: B
NEW QUESTION 55
A consultant has deployed a Nutanix cluster with AOS 5.10.x, then discovers the customer's environment is running on AOS 5.6.x. The consultant decides to re-image the cluster using the foundation Java applet. During the Foundation discovery, all cluster nodes display a status of Unavailable.
What should the consultant do to resolve the issue?
- A. Reset the IPMI IP addresses.
- B. Use the Phoenix ISO
- C. Destroy the cluster.
- D. Restart the Genesis service on the cluster.
Answer: C
NEW QUESTION 56
A consultant creates three storage containers (container-1, container-2, container-3). The customer requires that only container-1, which will be utilized as an NFS datastore, be presented to external hosts.
However, users are able to mount all three containers.
What is causing this problem?
- A. A Container-level whitelist entry was configured.
- B. A Global whitelist entry was configured.
- C. Compression was turned on for all containers.
- D. Deduplication was turned on for all containers.
Answer: B
NEW QUESTION 57
A customer wants to use NIC teaming on an ESXi host using a vSphere Standard Switch configured with the Route based on physical NIC load load balancing option. The customer does not see the option when editing the Teaming and Failover settings for the switch.
How should the consultant resolve this issue?
- A. Add a vSphere Distributed Switch
- B. Install a vCenter server to manage the switch
- C. Add another physical NIC to the team.
- D. Change the load balancing option on the switch.
Answer: A
NEW QUESTION 58
An existing Nutanix customer has several clusters in production and is adding a new cluster. The customer wants to create an AHV cluster that has already been racked and powered on remotely, with the factory image, using Prism Central.
Which step should the consultant take next?
- A. Build the cluster with the Foundation Applet
- B. Build the cluster with the Foundation VM.
- C. Build the cluster with Foundation Central.
- D. Bare metal image the nodes with the Foundation VM.
Answer: A
NEW QUESTION 59
......
Nutanix NCSC-Level-1 Pre-Exam Practice Tests | ExamDumpsVCE: https://www.examdumpsvce.com/NCSC-Level-1-valid-exam-dumps.html
