Real SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Exam Dumps with Correct 152 Questions and Answers
Valid Hybrid-Cloud-Observability-Network-Monitoring Test Answers & SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Exam PDF
NEW QUESTION # 62
NetFlow and CBQoS monitoring can be disabled through web console settings. If NetFlow monitoring is disabled for a node or interface, the data collection is stopped. Which two of the following statements are true regarding disabling NetFlow monitoring? (Choose two.)
- A. historical data is retained within the database
- B. enabling and disabling flow collection will not cause gaps within NTA graphs
- C. historical data is removed from the database
- D. enabling and disabling flow collection can result in gaps within NTA graphs
Answer: A,D
NEW QUESTION # 63
Which two of the following locations can hardware health be enabled? (Choose two.)
- A. manage MIB
- B. main settings
- C. list resources
- D. asset inventory
Answer: A,C
NEW QUESTION # 64
A device studio poller is being built for a router statistic. It is determined that its object ID (OID) does not exist in SolarWinds' MIB database. What is the best workaround for this situation?
- A. download database from customer portal
- B. select manually define object identifier and specify SNMP
- C. consult vendor and add OID to the database
- D. select SNMP and ICMP as the router's polling method
Answer: B
NEW QUESTION # 65
SNMP get type defines the SNMP polling method used by a universal device poller (UDP) to get the device's object ID (OID) values.
Which SNMP get type retrieves values from a particular column?
- A. column
- B. data
- C. table
- D. next
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
In SolarWinds Universal Device Poller (UDP), the column get type is used to retrieve values from a particular column of an SNMP table, meaning you get all the values for that column across multiple rows.
Reference:
"The 'Column' get type in Universal Device Poller retrieves all values in a specified column of an SNMP table, as opposed to just a single value or an entire table."
- (Network Performance Monitor Administrator Guide, Universal Device Poller SNMP Get Types section)
NEW QUESTION # 66
To which port does log analyzer forward secure syslog when a log forwarding custom rule action is set to TCP?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 67
A router has been added for health and performance monitoring in hybrid cloud observability, however default SNMP polling data is not visible. Additional network devices have been added and SNMP metrics for those devices are now visible.
How should this issue be resolved?
- A. Perform an MIB database update to update the default
- B. Perform an MIB database update and build custom pollers to monitor the device.
- C. Perform an SNMP walk and add the devices MIB file to SolarWinds' MIB database.
- D. Perform a firmware upgrade on the device to update its MIB file.
Answer: C
NEW QUESTION # 68
Which two of the following locations can hardware health be enabled? (Choose two.)
- A. manage MIB
- B. main settings
- C. list resources
- D. asset inventory
Answer: C,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Hardware health monitoring can be enabled during node discovery or after a node is added via the "List Resources" option. Additionally, hardware health can be enabled or viewed in the Asset Inventory page for nodes that support it.
From the documentation:
"You can enable hardware health sensors by selecting the option during resource discovery (List Resources) or later via Asset Inventory for individual nodes." References:
NPM Administrator Guide: Enabling Hardware Health
NEW QUESTION # 69
Which two of the following statistics are available for network capacity planning? (Choose two.)
- A. node temperature
- B. receive utilization on interfaces
- C. disk space forecast
- D. memory usage data on nodes
Answer: B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
SolarWinds provides several statistics for network capacity planning, most notably:
Memory usage data on nodes: Useful for forecasting resource exhaustion on network devices.
Receive utilization on interfaces: Essential for predicting bandwidth saturation and planning upgrades.
The documentation states:
"Key statistics for network capacity planning include interface utilization trends (receive and transmit) and memory utilization, which allow for forecasting and proactive infrastructure management." References:
Network Performance Monitor Administrator Guide, "Capacity Planning and Trending" SolarWinds Success Center: "Network Capacity Planning"
NEW QUESTION # 70
Which statement related to flow alerts is true?
- A. object of the alert selected from create a flow alert panel
- B. have no trigger actions
- C. can be triggered even when NetFlow service is down
- D. based on custom SQL query
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When you create a flow alert in SolarWinds, the object of the alert (such as a specific interface, node, or application) is chosen from the "Create a Flow Alert" panel. Flow alerts are not based on custom SQL queries, require the NetFlow service to be running, and always have associated trigger actions.
Reference:
NTA Administrator Guide, "Creating Flow Alerts,"
"In the Create a Flow Alert panel, you select the object to be monitored for flow-based alerting."
NEW QUESTION # 71
Which two of the following requirements apply to network capacity planning? (Choose two.)
- A. All object IDs (QIDs) of network devices are polled in hybrid cloud
- B. Updated MIB database for network performance forecasting.
- C. Enough historical data is available for the last 7 days.
- D. Nodes, interfaces, and volumes must be managed in HCO.
Answer: C,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
For effective network capacity planning:
Enough historical data (at least 7 days) must be available: This ensures meaningful trend and forecast analysis.
Relevant objects (nodes, interfaces, volumes) must be managed: Only managed entities are included in capacity planning calculations.
Polling every OID or updating the MIB database (A, D) is not a direct requirement for capacity planning.
Reference:
NPM Administrator Guide, "Capacity Planning Prerequisites and Requirements"
NEW QUESTION # 72
A universal device poller (UDP) and a transformer are built to display a transform value for a node's CPU temperature, however the value is not transformed as displayed on the web console. Which two of the following reasons could have caused the issue? (Choose two.)
- A. custom poller used for transformation is not assigned to same node
- B. node pollinginterval does not match the custom poller interval
- C. pollinginterval for thecustom poller is usingthe default value
- D. custom poller and transformer are not using same polling interval
Answer: A,D
NEW QUESTION # 73
Which tool presents live flow traffic data sourced from / to a main polling engine server, providing basic insight into traffic on the main polling engine?
- A. local NetFlow source
- B. collector service
- C. flow navigator
- D. CBQoS/flow sources
Answer: A
NEW QUESTION # 74
Which two of the following technologies are used when building device studio pollers? (Choose two.)
- A. VLAN and VRF on a dedicated widget
- B. power supply status for vital statistics view
- C. machine type for node details widget
- D. CPU and memory load of single processor
Answer: B,C
NEW QUESTION # 75
Which two of the following troubleshooting steps can be performed when a node is "up" and the data cannot be found in SolarWinds' platform web console? (Choose two.)
- A. Verify hardware health sensors on the device provide both status and values.
- B. Wait ten minutes after a device is added to the console. Refresh the screen.
- C. Add a remote site node and make sure the firewall rules are configured to allow SNMP traffic.
- D. Ping the device from the polling engine the device is assigned to using the command line.
Answer: A,D
Explanation:
Ping the device from the polling engine: Verifies network connectivity and correct polling engine assignment.
Verify hardware health sensors: Ensures the platform is receiving valid sensor data; missing data may indicate sensor or device communication issues.
Adding a remote site node and waiting are not direct troubleshooting steps for missing data on a node that is already "up." Exact Extract from Official Guide:
"If a node is up but data is missing, check network connectivity from the polling engine using ping or SNMP walk tools, and verify that hardware health sensors are reporting valid data."
- (Network Performance Monitor Administrator Guide, "Troubleshooting Nodes and Data Collection" section) References:
NEW QUESTION # 76
The web console is showing the status of a network router as "down", however the node is up and running.
Which two of the following causes could be creating the issue? (Choose two.)
- A. SNMP is blocked between the device and the polling engine
- B. ICMP is blocked between the device and the polling engine
- C. router is configured as a parent in a node dependency
- D. agent connection status with the polling engine is "down'
Answer: A,B
NEW QUESTION # 77
Which two of the following requirements must be met to detect duplex mismatches? (Choose two.)
- A. nodes must be in "up" status
- B. nodes must be monitored
- C. nodes must be described in MIB
- D. nodes must be in 'warning' status
Answer: A,B
NEW QUESTION # 78
Which two of the following tasks must be accomplished to monitor servers and connections in a load- balancing environment? (Choose two.)
- A. enable F5 iControl polling
- B. add Cisco Nexus device in network health / performance monitoring
- C. add Cisco Nexus device in network device configuration manager
- D. enable CLI polling
Answer: A,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To monitor servers and connections in a load-balancing environment-specifically for F5 BIG-IP load balancers-SolarWinds requires that you:
Enable CLI polling: This is necessary for SolarWinds to collect configuration and health data from network devices.
Enable F5 iControl polling: F5 iControl API allows SolarWinds to collect load balancer details, including virtual servers and pools, for deep monitoring of server and connection health.
Adding Cisco Nexus devices relates to switch monitoring and is not required for F5/BIG-IP load balancer server connection monitoring.
Exact Extract from Official Guide:
"To fully monitor F5 BIG-IP load balancers, enable both SNMP and CLI polling, and configure F5 iControl API credentials for device access and load balancing visibility."
- (Network Performance Monitor Administrator Guide, "Network Insight for F5 BIG-IP" section) References:
Network Performance Monitor Administrator Guide, Network Insight for F5 BIG-IP
NEW QUESTION # 79
A network discovery profile for a network area completes with most devices discovered, except for a few SNMP enabled network devices. These undiscovered devices are verified to be operational and respond to SNMP queries.
What could be the cause?
- A. discovery timeout value is set too low
- B. no SNMP pollers match the device
- C. device MIB is not in SolarWinds' MIB database
- D. SNMP community strings in profile are invalid
Answer: D
NEW QUESTION # 80
......
Hybrid-Cloud-Observability-Network-Monitoring Exam Questions and Valid PMP Dumps PDF: https://www.examdumpsvce.com/Hybrid-Cloud-Observability-Network-Monitoring-valid-exam-dumps.html