[Jan 08, 2025] Pass EMC D-VXR-DY-23 Exam Info and Free Practice Test
D-VXR-DY-23 Exam Dumps PDF Updated Dump from ExamDumpsVCE Guaranteed Success
NEW QUESTION # 160
For which typical activity would the No data migration setting be used when placing a VxRail host into maintenance mode?
- A. Shutting down an entire cluster
- B. Temporary maintenance
- C. Relocating host to remote data center
- D. Permanently removing host from cluster
Answer: A
NEW QUESTION # 161
After the installation of a VxRail cluster, the vSAN Health Check shows a hardware compatibility warning.
Where can detailed information about this health check and its resolution be found?
- A. vCenter Server Help
- B. VxRail Manager Help
- C. VMware Knowledge Base
- D. Dell EMC Knowledge Base
Answer: C
NEW QUESTION # 162
What is a benefit of using the VxRail REST API?
- A. Polling for vSAN performance statistics
- B. Remote upgrades of iDRAC related software only
- C. Automated log collection for VxRail clusters
- D. Automated security audit of VxRail clusters
Answer: C
NEW QUESTION # 163
What is a benefit when using VxRail-Managed vCenter?
- A. Ease of operation for lifecycle management.
- B. Ease of VM Migration across multiple clusters.
- C. Additional virtual distributed switch options.
- D. Enhanced security requirements.
Answer: A
NEW QUESTION # 164
What must be enabled on ToR switch ports connected to VxRail nodes to support multiple VLANs?
- A. Access Mode
- B. Trunk Mode
- C. Link Aggregation
- D. Rapid Spanning Tree
Answer: B
NEW QUESTION # 165
For which VxRail model must the iDRAC NIC Selection be set to LOM1?
- A. D Series
- B. E Series
- C. G Series
- D. S Series
Answer: C
NEW QUESTION # 166
A 4 node VxRail solution will be deployed.
Based on the exhibit, what will be the host name assigned to the last node in the cluster?
- A. MyVxRail-d.mycompany.com
- B. MyVxRaild.mycompany.com
- C. MyVxRail04.mycompany.com
- D. MyVxRail-4.mycompany.com
Answer: A
NEW QUESTION # 167
You are configuring a VxRail to connect to an existing, external SRS VE. The customer's support account is associated with the Site ID/Party ID where VxRail is installed. A validation error is issued when you attempt to register VxRail in SRS.
What is the possible cause for the error?
- A. Status of VxRail in Install Base is Shipped
- B. Number of deployed devices on SRS gateway has exceeded the maximum
- C. SRS traffic goes through a proxy server
- D. Wrong IP address was used for SRS VE gateway
Answer: A
NEW QUESTION # 168
What is the maximum number of VxRail 4.7.x Clusters you can create with three G Series nodes and five E Series nodes?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 169
When installing VxRail hardware and configuring iDRAC settings, which methods can be used per SolVe documentation?
- A. Using System Setup during Post
Micro USB Direct connection to node - B. Using Lifecycle controller interface
DB9 to USB cable to configure - C. Press F2 on post, use System setup
DB9 to USB cable to configure - D. Press F10 on post, use System setup
Use Lifecycle controller interface
Answer: A
NEW QUESTION # 170
Which service determines the primary node after powering on the VxRail nodes during the deployment of a VxRail cluster?
- A. Mystic
- B. Marvin
- C. Loudmouth
- D. Election
Answer: D
NEW QUESTION # 171
What action is required to enable VxRail Manager the ability to update system software and browse VxRail KB articles?
- A. Enable Secure Remote Support (SRS)
- B. Configure Proxy settings
- C. Set the appliance status to 'Installed' in the Dell EMC Install database
- D. Set the Username and Password for the Support Account
Answer: D
NEW QUESTION # 172
What is the difference between Compression only and Deduplication and compression on a VxRail vSAN cluster?
- A. Compression only: Does not require a rolling reformat of the disks when enabled Deduplication and compression: Requires a rolling reformat of the disks when enabled
- B. Compression only: A failed capacity disk causes the disk group to go offline Deduplication and compression: A failed capacity disk does not impact the entire disk group
- C. Compression only: Added capacity disk requires a disk group rebuild
Deduplication and compression: Added capacity disk does not require a disk group rebuild - D. Compression only: A failed capacity disk does not impact the entire disk group Deduplication and compression: A failed capacity disk causes the disk group to go offline
Answer: D
NEW QUESTION # 173
Where can an administrator find steps to perform a manual verification of the customer network?
- A. Dell Technologies SolVe Online
- B. Customer Simplified Form
- C. Dell EMC VxRail Network Planning Guide
- D. Pre-Engagement Questionnaire (PEQ)
Answer: A
NEW QUESTION # 174
A VxRail deployment has been completed. The implementation engineer wants to generate the As-Built Configuration report.
How do they obtain the required VxRail XML file?
- A. Download it from the vSphere Client - VxRail Last Configuration Data Sent
- B. Use FTP to copy the file from the VxRail Manager VM
- C. Download it from the VxRail Deployment Wizard after a successful deployment
- D. Generate it from the VxRail PEQ by clicking the Create PEQ Data File button
Answer: A
NEW QUESTION # 175
You have been asked to deploy a single, 4 node VxRail cluster for company. They would like to migrate from their existing vSphere 6.5 environment. They have also asked that vCenter Enhanced linked-mode be supported.
Based on best practice, what is the recommended deployment model?
- A. Use existing vCenter 6.5 with External PSC
- B. Use existing vCenter 6.5 with Embedded PSC
- C. Deploy Internal vCenter with Embedded PSC
- D. Deploy Internal vCenter with External PSC
Answer: C
NEW QUESTION # 176
......
Pass Your EMC Exam with D-VXR-DY-23 Exam Dumps: https://www.examdumpsvce.com/D-VXR-DY-23-valid-exam-dumps.html
D-VXR-DY-23 Exam Dumps - EMC Practice Test Questions: https://drive.google.com/open?id=1OEwGIAhPW3NsNMVIxp2XA1qPPwX034NW